Honeywell

Valves & automation for reliable processes

Armaturenfabrik Honeywell Armatur pressure regulating valves DRV

Honeywell – Shut-off and control technology for industry, energy & HVAC

Honeywell stands for robust valves and reliable automation components in industrial, energy and HVAC systems. As an Armaturenfabrik, we combine this portfolio with engineering, modification and complete system integration: from the selection of suitable valves and drive technology to ready-to-install delivery with documentation. The result: reliable processes, efficient control and fast commissioning.

Honeywell valves globe valves and control technology and automation Logo

Product focus

Armaturenfabrik added value: We supply fully assembled units – valve + actuator + limit switches/solenoid valves + mounting bridge + documentation (e.g. 3.1, test reports, CE/DRGL) – ready for installation in your system.

Globe valves & ball valves

For safe shut-off and precise control of liquids, gases and steam.

Solenoid valves & control components

For reliable automation in HVAC, energy and process industries.

Check valves & safety components

Protection against backflow, pressure surges and fault currents.

Automation

Pneumatic/electric actuators, limit switches, position indicators; MSR integration.

Special versions

For ATEX areas, high temperatures, aggressive media; connection standards according to EN/ASME.

Areas of application for Honeywell valves

Food & Beverage

CIP/SIP

Hygienic solenoid and shut-off valves with FDA compliant seals; CIP/SIP capable versions.

Chemicals & Pharmaceuticals

Chemische Industrie, Pharma, Petrochemie

Valves and solenoid valves for aggressive media and hazardous zones; matching sealing systems.

Energy & Power Plants

Kraftwerksbau, Dampfsysteme, LNG

Ball valves and shut-off valves for steam/hot water/
condensate; actuators including position feedback.

Water &
wastewater

Drinking water, wastewater technology, HVAC

HVAC and supply: solenoid valves, check valves, control components for circuits and treatment.

Oil & Gas

Explosionsschutz, Hochdruck

ATEX capable ball valves/
solenoid valves; seawater-resistant options project-specific.

Mechanical & plant engineering

Automation, MSR technology

ISO-5211-compatible valves for skids, automation and MSR integration.

Your advantages with Honeywell & Armaturenfabrik

Consulting & Engineering

Design of valve, gasket, actuator and interface according to medium, p/T and standard.

Modification & individualization

Special flanges, position feedback, heating jacket/insulation, special connections & materials.

Complete systems from a single source

Valve + actuator + solenoid valves/limit switches + mounting bridge + documents – ready for installation.

HVAC & energy expertise

Experienced in heating/cooling/steam circuits, condensate management and supply networks.

Standards & safety practice

CE/DGRL-compliant, ATEX options, clear test documents and traceability.

Deadline & quality commitments

Transparent delivery dates, tested quality, complete project documentation.

Pressure ranges, nominal sizes and connections at Honeywell

Ohne Hilfsenergie

Die Druckminderer D06-F and D15 regeln membrangesteuert and federbelastet.

Inlet pressure up to 25 bar

The D06-F accepts up to 25 bar, and the outlet pressure is adjustable from 1 to 6 bar.

Bis DN 200

The flanged version D15S in ductile iron and D15P in grey cast iron extends to DN 200.

Manometer beidseitig

The D06-F has connections for inlet and outlet pressure – without additional fittings.

Maintenance without draining

On the EA 122 the internals can be replaced without draining the system.

Drei Funktionen im EA 122

Shut-off, leak protection with swell discs and a vacuum breaker in one body.

A selection of products

The Honeywell range at Armaturenfabrik

We trade in Honeywell valves and supply from the manufacturer range. The four series described below are the ones we supply most often – we can source the complete Honeywell range, including series not listed here.

Pressure reducing valves: thread or flange

The size determines the design. Up to DN 20 the compact brass version with a thread is the choice; above that, the flanged version in cast iron.

SeriesConnection and materialNominal sizePressuresTemperature
D06-Fthread R 1/2″ and R 3/4″, body in brassDN 15 and DN 20inlet pressure up to 25 bar, outlet pressure adjustable from 1 to 6 barup to 70 °C
D15S / D15Pflange, body in ductile iron and grey cast iron respectivelyup to DN 200inlet pressure up to 16 bar, outlet pressure up to around 10 barup to 70 °C

Both are diaphragm-controlled and spring-loaded – they regulate without auxiliary power. The D06-F has pressure gauge connections on both sides, so inlet and outlet pressure can be read without additional fittings.

Air vent and float valve

SeriesFunctionCharacteristics
EA 122quick air vent for hot water heating systemsconnection R 1/8″ + 3/8″ or R 1/4″ + 3/8″, connection part in brass, max. 6 bar, up to 110 °C; with a built-in shut-off, leak protection by swelling discs and an integrated vacuum breaker – the internals can be cleaned and replaced without draining the system
VR170 / ZN170float valve for level controlbrass, connections R 1/2″ to R 2 1/2″, operating pressures from 3 to 8 bar, up to 90 °C

What distinguishes the EA 122 in operation

The three functions in one housing save components and downtime: the built-in shut-off allows maintenance during operation, the leak protection with swelling discs closes automatically in the event of a leak, and the integrated vacuum breaker prevents a vacuum during draining. In heating systems this replaces three separate fittings.

Optional: adaptations to Honeywell valves

As a rule we supply Honeywell products unchanged from the manufacturer range. Where the project requires it, the following can be added for Honeywell:

  • threaded or flanged version depending on the nominal size
  • outlet pressure range of the pressure reducing valve to suit the operating point
  • connection variant of the EA 122 in R 1/8″ + 3/8″ or R 1/4″ + 3/8″
  • pressure reducing valve with pressure gauge and strainer as one unit

FAQs

Can Honeywell be used for CIP/SIP and hygiene?

Yes, with FDA-compliant gaskets/materials and suitable connection standards, use in hygienic processes is possible.

Yes, ATEX is available on a project-specific basis – including actuator/peripherals and complete documentation.

Yes, valve + actuator + solenoid valves/limit switches + documents; with heating jacket/insulation on request.

Flanges EN 1092-1 / ASME B16.5, thread EN ISO 228, butt weld ends; ISO-5211 for actuator mounting.

Through defined test scopes (pressure/leakage/function), 3.1 certificates, CE/DGRL documentation and binding schedules.