Endress+Hauser is one of the world’s leading suppliers of process measurement technology and automation solutions. As a valve manufacturer, we integrate this measurement technology into complete systems – including valves, automation and documentation. Whether flow, pressure, temperature or level: we deliver solutions that make your processes safer, more efficient and more transparent.
For liquids, gases and steam – magnetic-inductive, ultrasonic or Coriolis.
For precise pressure monitoring in pipes and tanks.
For level control and temperature monitoring in sensitive processes.
Complete solutions with I&C technology, control and data connection.
For Ex zones, hygienic applications and aggressive media.
CIP/SIP
Hygienic measurement technology for level, temperature and flow.
Pressure and flow meters for aggressive media, ATEX-compliant devices.
Steam measurement, condensate
monitoring and temperature control.
Flow and level monitoring for treatment and circulation systems.
Precise measurement technology for high-pressure and safety
applications.
Integration of measuring devices in automated systems.
The Proline Promag 50P measures media up to +180 °C, electromagnetically.
Standard -40 to +260 °C, optionally -200 to +400 °C, on request up to +450 °C.
Maximum process pressure of the Proline Prowirl D 200.
Measuring tube in contact with the medium in 1.4408, equivalent to CF3M.
Application-specific lining materials are available for the Promag.
The integrated temperature measurement of the Prowirl allows mass and energy flow from a single device.
We trade in measuring technology from Endress+Hauser and supply from the manufacturer range. The two instruments described below are the ones we supply most often – we can source the complete Endress+Hauser range, including instruments not listed here.
The most important question before selection is not the nominal size but the medium. An electromagnetic instrument measures only electrically conductive liquids – the flowing medium is itself the moving conductor. For steam, gases and non-conductive media a vortex flowmeter is therefore used.
| Instrument | Measuring principle | Suitable for | Temperature | Features |
| Proline Promag 50P | electromagnetic | electrically conductive liquids | medium up to +180 °C | application-specific lining materials; software options for batching and electrode cleaning |
| Proline Prowirl D 200 | vortex flowmeter | steam, gases and liquids | standard −40 to +260 °C · option −200 to +400 °C · up to +450 °C on request | maximum process pressure PN 40, Class 300 or 20K; measuring tube in 1.4408 (CF3M); integrated temperature measurement for mass and energy flow; insensitive to thermal shock and water hammer |
The Prowirl D 200 is therefore the instrument for steam applications: the integrated temperature measurement allows mass and energy flow to be calculated from a single device, and insensitivity to water hammer is no minor matter in steam networks.
As a rule we supply the Endress+Hauser series version. Beyond that the following is possible with Endress+Hauser – optional, not a precondition:
Yes – lining, temperature version and connection can be selected; integration into existing systems.
For conductive liquids with the Promag, for steam and gases with the Prowirl.
Yes, on request as a complete measuring section with shut-off valve and documentation.
The starting point is your enquiry with medium, pressure and temperature. From this we size the appropriate Endress+Hauser version and agree the accessories and test scope with you.
Because Endress+Hauser offers a suitable measuring principle for every medium – and because of our experience as an integration partner.