SKU DRV-4123 Category Brand:

Pressure reducing valve type 41-23

Universal pressure reducing valve without auxiliary energy

Data sheet

Product information

The SAMSON universal pressure reducing valve type 41-23 is a self-acting pressure regulator without an external power supply. It consists of the type 2412 valve and the type 2413 actuator. The regulator keeps the pressure downstream of the valve constant at the set point – independently of fluctuations in the inlet pressure.
It is suitable for liquid, gaseous and vaporous media in process and industrial plants.

Special features

  • Control without an external power supply
  • For liquids, gases and steam
  • Maximum temperature: up to 350 °C
  • Set point ranges: 0.05 to 28 bar
  • Nominal sizes: DN 15 to DN 100
  • Nominal pressures: PN 16 to PN 40
  • Leckage-Klassen: Metallisch dichtend: Klasse I and Weich dichtend: Klasse IV
  • CE compliant to the Pressure Equipment Directive 2014/68/EU and the Machinery Directive 2006/42/EC

Versions

  • Diaphragm actuator for set point ranges from 0.05 to 16 bar
  • Bellows actuator for high set points up to 28 bar
  • FDA version for food applications
  • Special versions for aggressive media and high temperatures

Areas of application

  • Dampfnetze, in denen the Vordruck schwankt and the Hinterdruck konstant bleiben muss
  • Hot water circuits up to 350 °C with an upstream expansion vessel
  • Gas lines and compressed air networks without available control air
  • Prozessanlagen, in denen keine elektrische Energie am Regelpunkt liegt

Advantages

  • Controls without an external power supply – neither electricity nor control air is required
  • Sollwertfeder, Sitz, Kegel and Stellmembran im Feld austauschbar
  • Set point range from 0.05 to 28 bar via two actuator types
  • Leakage class I metal-seated or class IV soft-seated selectable

Selection and installation

The set point range determines the actuator: up to 16 bar the type 2413 diaphragm actuator, above that the bellows actuator up to 28 bar. From a medium temperature of 150 °C an expansion vessel must be provided; the insulation must leave the actuator free.

FeatureValue
Nominal sizeDN 15 – DN 100
Nominal pressurePN 16, PN 25 , PN 40
Control mediumliquid, gaseous, vaporous
Temperature rangeto 350 °C (with expansion vessel)
Set point ranges0.05–28 bar (depending on from actuator)
SealsPTFE, EPDM, NBR, FKM
Materials

grey cast iron, ductile iron, cast steel, stainless steel

FAQs

Which applications is the pressure reducing valve type 41-23 suitable for?

Liquid, gaseous and vaporous media.

Up to 350 °C (with expansion tank).

0.05-28 bar, depending on the actuator.

Pressure Equipment Directive 2014/68/EU, Machinery Directive 2006/42/EC.

Insulation – In combination with valves and containers

Our insulations are more than just accessories – they perfectly complement valves and systems and increase efficiency, safety and adaptability.
Order and configure now.

We offer:

  • Custom-made insulating pads to fit your valves
  • Heating jacket integration – reliable even under extreme conditions
  • Insulation jackets and pipe insulation for SKID assemblies – ideal for modular systems and complex systems
  • Special solutions for high temperatures – for power plants, the chemical and process industries
Armaturenfabrik Valve insulation High-temperature pipe insulation with IFS-Plast25 insulation pads and IFS-MW20 mineral wool for SKID systems, process plants

Make a request directly

Would you like individual advice?

Benefit from our expert knowledge in process monitoring. Our experienced team will provide you with sound advice on selecting the optimum products for your specific requirements. Arrange your personal consultation now!
Cookie Consent with Real Cookie Banner